supported_hardware:hubitat
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
supported_hardware:hubitat [2021/02/10 14:41] – James Sentman | supported_hardware:hubitat [2021/11/05 15:44] – added gathering data for support section James Sentman | ||
---|---|---|---|
Line 31: | Line 31: | ||
If you have only a single Hubitat on your network you can leave the defaults for **Address** as " | If you have only a single Hubitat on your network you can leave the defaults for **Address** as " | ||
- | If you are running multiple Hubitat' | + | If you are running multiple Hubitat' |
+ | |||
+ | **NOTE:** there is a bug somewhere either in their firmware or in the Mac implementation of the bonjour lookups that can make it take between 5 and 10 seconds or more to resolve the hubitat.local address. Until I or they figure out what changed and how to fix it please use a DHCP reservation or the static IP capabilities of the more recent firmware updates and change the address of the hubitat in the XTension address field to use the IP address instead of the mDNS name. This will remove the extended delay when controlling anything that many folks, including myself, but not all folks are seeing when using the hubitat.local address. | ||
If you have setup local access security on the Hubitat check the "Send Authentication" | If you have setup local access security on the Hubitat check the "Send Authentication" | ||
Line 42: | Line 44: | ||
---- | ---- | ||
+ | |||
+ | ====Unit Naming Conventions: | ||
+ | When XTension sees a new unit in the Hubitat it will automatically create a new unit for it with all the proper settings. It will also use the name you have given the unit in the Hubitat as it’s starting point. Once the unit is created the name of the unit is no longer important to the connection and you can change the name in XTension without changing it in the Hubitat. This can be useful if there are name length restrictions or if the naming convention you are using inside the hubitat would not be as useful as what you want to use in XTension. | ||
====Using The Hubitat Plugin:==== | ====Using The Hubitat Plugin:==== | ||
Line 73: | Line 78: | ||
- | **Note:** as of this beta version there is not yet an " | + | **NOTE:** The default |
- | + | ||
- | **NOTE:** Unlike the Vera it seems that the Hubitat | + | |
**Device Notifications: | **Device Notifications: | ||
+ | |||
+ | ===Scene Controllers: | ||
+ | As of XTension 9.4.41 scene controllers and other devices with buttons or inputs should again behave properly. Wireless scene controllers will now create a single unit in XTension. It will not change state itself, but it will receive central scene events about which button was pressed and the number of clicks as available. Hold and release are handled the same as the examples above for switches. | ||
+ | |||
+ | |||
+ | ====Controlling Status LEDs:==== | ||
+ | As of XTension 9.4.41 you can now control the status LED’s of the Home Seer WD200+ dimmers. Please see the [[supported_modules: | ||
====Things That Are Not Implemented Yet:==== | ====Things That Are Not Implemented Yet:==== | ||
Line 87: | Line 97: | ||
Sensor type devices that should be controllable, | Sensor type devices that should be controllable, | ||
- | |||
- | As of this moment it does not appear that setting of device firmware data is supported by the Hubitat protocol. So things like setting the LED display colors on the Innovelli or Home Seer switches is not yet possible. I hope to either have this sorted out or to have a feature request in to the Hubitat folks to implement it as soon as possible but since it is up to them on their side I cannot guarantee when or if this will ever work properly. It is something I make a lot of use through the Vera and so I will be pushing hard to find a way to make this work. It does appear that the hub itself supports setting this information. It is just a matter of bringing it out to the MakerAPI protocol so that we can do it remotely. | ||
The support for location events, control of modes and control of the " | The support for location events, control of modes and control of the " | ||
Line 110: | Line 118: | ||
set value of “Thermostat Mode Unit” to “cool” | set value of “Thermostat Mode Unit” to “cool” | ||
</ | </ | ||
+ | |||
+ | |||
+ | ====Gathering Data For Unsupported Devices: | ||
+ | If you have a device that is either not showing up at all or it showing no updates or the wrong updates please do the following to capture info about it. First I need a full database dump from your hubitat and the name of the device or it’s address so I can find the pertinent data in the potentially large database info. Please visit this link on your Hubitat, filling in your Access Token as described above in the initial setup: | ||
+ | |||
+ | < | ||
+ | http:// | ||
+ | </ | ||
+ | |||
+ | That will download some pages of JSON data into your browser, you can cut and paste it into an email to me or save it to a file and email me that if the data is too large. | ||
+ | |||
+ | Second I will need some of the push data that the hubitat sends when values change or are updated. In the Interface List window in XTension control click, or perform a contextual click on the hubitat interface you created there and select “Turn Debug Mode On” Now all the push information that is received will be written to the XTension log. Do whatever you need to in order to create some push updates from the Hubitat and then copy and paste those lines into an email to me as well. I’ll do whatever possible to support any devices that aren’t already handled properly. | ||
====History: | ====History: | ||
Line 115: | Line 135: | ||
* Thermostats are working as of XTension version 9.4.36 plugin version 1.1 | * Thermostats are working as of XTension version 9.4.36 plugin version 1.1 | ||
* Ceiling Fan control is working as of XTension version 9.4.37 plugin version 1.2 | * Ceiling Fan control is working as of XTension version 9.4.37 plugin version 1.2 | ||
+ | * Scene Controllers are working as of XTension 9.4.41 |
supported_hardware/hubitat.txt · Last modified: 2023/11/04 13:49 by James Sentman